"Gateway to the World Since 1963"
- Manufacturing Industrial, Screen Printing, and Garment decorating Equipment -
Model Number HG 3612 BG 4820 BG 6020 BG 7220
220V Range
Electricl Requirments 1-Ph, 5 Amps, 60Hz 3-Ph, 10 Amps, 60Hz 3-Ph, 10 Amps, 60Hz 3-Ph, 10 Amps, 60Hz
Minimum Circuit Amps 10 Amps 20 Amps 20 Amps 20 Amps
Maximum Fuse Size 10 Amps 20 Amps 20 Amps 20 Amps
 
Overall Length 12ft (366cm) 20ft (606cm) 20ft (606cm) 20ft (606cm)
Heated Oven Length 6ft (183cm) 11ft (335cm) 11ft (335cm) 11ft (335cm)
Conveyor Infeed 2ft (61cm) 4ft (122cm) 4ft (122cm) 4ft (122cm)
Conveyor Delivery 2ft (61cm) 3ft (91cm) 3ft (91cm) 3ft (91cm)
Fume Hoods - Each End 1ft (30.5cm) 1ft (30.5cm) 1ft (30.5cm) 1ft (30.5cm)
Frame Width 48" (122cm) 60" (152cm) 72" (183cm) 84" (213cm)
Overall Width (control box and air plenum box installed) 55" (140cm) 89" (226cm) 101" (256cm) 113" (287cm)
Height (floor to top of exhaust) 69" (175cm) 83-1/2" (212cm) 83-1/2" (212cm) 83-1/2" (212cm)
Belth Height From Floor 34" (86cm) 34" (86cm) 34" (86cm) 34" (86cm)
Belth Width 36" (91cm) 48" (122cm) 60" (152cm) 72" (183cm)
 
Belt Type TCF (PTFE Coated Fiberglass) TCF (PTFE Coated Fiberglass) TCF (PTFE Coated Fiberglass) TCF (PTFE Coated Fiberglass)
Belt Speed 0 - 17 FPM (0 - 5 m/min) 0 - 17 FPM (0 - 5 m/min) 0 - 17 FPM (0 - 5 m/min) 0 - 17 FPM (0 - 5 m/min)
Belt Speed Control Analog Knob 0-10 Analog Knob 0-10 Analog Knob 0-10 Analog Knob 0-10
Temperature Control Digital (with Hi/Low temp alarm) Digital (with Hi/Low temp alarm) Digital (with Hi/Low temp alarm) Digital (with Hi/Low temp alarm)
Oven Temperature Accuracy +/-5F (2C) of set point +/-5F (2C) of set point +/-5F (2C) of set point +/-5F (2C) of set point
 
Maximum Oven Temperature 400°F (204°C) 400°F (204°C) 400°F (204°C) 400°F (204°C)
Minimum Oven Temperature 250°F (120°C) 250°F (120°C) 250°F (120°C) 250°F (120°C)
BTU Input Minimum 39,000 BTU 100,000 BTU 100,000 BTU 100,000 BTU
BTU Input Maximum 85,000 BTU 300,000 BTU 300,000 BTU 300,000 BTU
 
Exhaust Airflow 450 CFM - 10 inch Duct (12,600 1/min - 25 cm duct) 1,300 CFM - 14" duct (36,400 1/min - 35 cm duct) 1,300 CFM - 14inch Duct (36,400 1/m - 35 cm duct) 1,300 CFM - 14" duct (36,400 1/min - 35 cm duct)
Exhaust Air Motors 1/10 H.P. direct drive 1/2 H.P. direct drive 1/2 H.P. direct drive 1/2 H.P. direct drive
 
Recirculating Airflow 1,000 CFM Fixed 2,600 CFM Fixed 2,600 CFM Fixed 2,600 CFM Fixed
Recirculating Air Motors 1 H.P. Two 1 H.P. direct drive AC 3-phase motors Two 1 H.P. direct drive AC 3-phase motors Two 1 H.P. direct drive AC 3-phase motors
 
Air Filters Fume Hood (None)
Combustion Air (None)
Recirculation Air (1)
Fume Hood (4)
Combustion Air (1)
Recirculation Air (2)
Fume Hood (4)
Combustion Air (1)
Recirculation Air (2)
Fume Hood (4)
Combustion Air (1)
Recirculation Air (2)
Minimum Distances To Other Surfaces For Installation
(suitable for use on Non-Combustible flooring only)
Back 18" (46cm) 18" (46cm) 18" (46cm) 18" (46cm)
Ends 40" (102cm) 40" (102cm) 40" (102cm) 40" (102cm)
Front 48" (122cm) 48" (122cm) 48" (122cm) 48" (122cm)
Flue To Surface 18" (46cm) 18" (46cm) 18" (46cm) 18" (46cm)
 
Indicator Lamps Interlocks Proven
Purging
Burner On
Interlocks Proven
Purging
Burner On
Interlocks Proven
Purging
Burner On
Interlocks Proven
Purging
Burner On
 
Interlocks High Temp Limit
Exhaust Purge Proving
Recirculation Proving (1)
Combustion Air Proving
Emergency Stop
High Gas Pressure
Low Gas Pressure
Exhaust Purge Proving
Recirculating Proving (2)
Combustion Air Proving
High Temp Limit
Emergency Stop
High Gas Pressure
Low Gas Pressure
Exhaust Purge Proving
Recirculating Proving (2)
Combustion Air Proving
High Temp Limit
Emergency Stop
High Gas Pressure
Low Gas Pressure
Exhaust Purge Proving
Recirculating Proving (2)
Combustion Air Proving
High Temp Limit
 
Flameguard (flame proving) Honeywell S87K Ignition Control Eclipse Flame Pack Eclipse Flame Pack Eclipse Flame Pack
 
Safety Standards Built to ANSI Z21.17 Built to UL-795 Built to UL-795 Built to UL-795
 
Gas Type Requirments Natural Gas Natural Gas Natural Gas Natural Gas
Gas Pressure Requirments 0.25 PSI / 7inch Water Column 1.0-5.0 PSI
(0.1-0.3 bar)
1.0-5.0 PSI
(0.1-0.3 bar)
1.0-5.0 PSI
(0.1-0.3 bar)
Gas Service Inlet 3/4inch NPT 3/4inch NPT 3/4inch NPT 3/4inch NPT
(Units made for Propane Gas available on special order)
Gas Pressure Propane 0.5 PSI / 34mbar 0.5 - 3.0 PSI
(0.05 - 0.22 bar)
0.5 - 3.0 PSI
(0.05 - 0.22 bar)
0.5 - 3.0 PSI
(0.05 - 0.22 bar)
Per Hour Consumption Estimate at 350F / 175C (at idle)
Electic 0.58KWH 2.5kW 2.5kW 2.5kW
Gas 0.053mcf 0.12MCF 0.13MCF 0.14MCF
In US$(electic @ $0.10/kWh; gas @ $6.50/MCF $0.40/hr $1.03/hr $1.10/hr $1.16/hr
1201 E. 27th Terrace • Pittsburg, KS 66762 U.S.A. • 1-620-231-8568
U.S. 1-800-835-0606 • U.S. Fax 1-620-231-1598
©2012 HIX Corporation